Industrial water and desalination
In a desalination or industrial water unit, the flow and quality of product water depend on the condition of the membranes, filters and pumps, and changes show up slowly, week by week. Waiotech keeps an orderly record of each unit and each machine side by side, whether it is reverse osmosis, process water or effluent reuse.
A month in the life of an RO unit
In this sample, the differential pressure of a reverse osmosis unit creeps up over the month and permeate falls. The data are a sample and not a design target for any unit.
- Conductivity · Feed
- 2,400 µS/cm
- Conductivity · Permeate
- 45 µS/cm
Stage 1 differential pressure
| Date | bar |
|---|---|
| 24 Oct 2026 | 1.2 |
| 31 Oct 2026 | 1.2 |
| 7 Nov 2026 | 1.4 |
| 14 Nov 2026 | 1.6 |
| 21 Nov 2026 | 1.7 |
Permeate flow
| Date | m³/h |
|---|---|
| 24 Oct 2026 | 70 |
| 31 Oct 2026 | 70 |
| 7 Nov 2026 | 68 |
| 14 Nov 2026 | 67 |
| 21 Nov 2026 | 66 |
Cartridge filter differential pressure
| Date | bar |
|---|---|
| 24 Oct 2026 | 0.4 |
| 31 Oct 2026 | 0.5 |
| 7 Nov 2026 | 0.7 |
| 14 Nov 2026 | 0.9 |
| 21 Nov 2026 | 1.0 |
- Cartridge replacements
- Antiscalant dosing
- Raw water quality
- High-pressure pump running hours
Flow balance
On 3 November, a feed of 100 m³/h produced 70 m³/h of permeate and 30 m³/h of concentrate, a recovery of 70%. Feed conductivity was 2,400 µS/cm and permeate 45 µS/cm.
Change over the month
Over the following weeks, the stage 1 differential pressure rises from 1.2 to 1.7 bar and, at the same feed, permeate falls to 66 m³/h. The cartridge filter differential pressure has risen from 0.4 to 1.0 bar.
Related records
The operating team reviews these changes against other records: when the cartridges were last replaced, the recorded antiscalant dosing, raw water quality and the high-pressure pump's running hours. What to do next is decided by the team, following the membrane manufacturer's guidance.
The unit's history beside the pressure trend
Differential pressure has risen. Before deciding on a chemical clean, the team reviews this unit's own history. The data are a sample.
| Date | Record |
|---|---|
| 18 Aug 2026 | Chemical clean (CIP) of both stages |
| 20 Oct 2026 | Cartridges replaced; pressure drop after the change 0.4 bar |
| 29 Oct 2026 | Antiscalant tank ran empty for two days; recorded dose zero |
| 12 Nov 2026 | Raw water turbidity above normal in two consecutive samples |
Two things stand out in this history: two days without antiscalant on 29 October and high raw water turbidity on 12 November. Which of them contributes to the rising pressure, and when to clean, is the team's call, following the membrane manufacturer's guidance. The software does not normalise membrane performance data.
What an industrial water facility records and reviews
- Units and streams
- The treatment units and the streams between them, from raw water to permeate and concentrate, are defined in the facility's structure, and each measurement point is tied to its unit and stream.
- Log books
- Flow, conductivity, differential pressure and other values are entered in log books. Abnormal conditions are seen alongside the record of the same unit.
- Duty groups and running hours
- Pumps, from the feed pump to the high-pressure pump, are defined as duty groups, and the running hours of each are recorded.
- Maintenance and parts
- The maintenance plan, work history and consumable parts of each machine, such as filter cartridges, are kept together.
Specialised reverse osmosis calculations, such as normalising membrane performance data, are not part of the software today. Industrial water is one of the areas Waiotech is being developed towards, and how well the software fits a particular unit is reviewed in an introductory meeting.
Reuse of effluent from wastewater plants links this area to wastewater treatment. Wastewater treatment
Your industrial water facility
If you run a reverse osmosis unit or effluent reuse, tell us what is recorded for it today. We will say in that meeting whether the software fits.