Product · Operations

Shift rounds, readings and process conditions, side by side.

The operator runs the round on a phone. When a reading falls out of range and an observation is recorded, the operations supervisor raises a process condition with “elevated” attention, and it shows on that unit of the plant.

Sample
08:24●●● ▮
KMorning shift round
In progress۰ of 5
Inlet flow900–2600 m³/h1860 m³/h
DO · basin 11.5–2.5 mg/L1.9 mg/L
DO · basin 21.5–2.5 mg/L0.9 mg/L
MLSS · basin 12800–3600 mg/L3240 mg/L
Observation
Brown foam on aeration basin 2
Process conditionElevated
Low dissolved oxygen in aeration basin 2
WW-U-AER-2 · Active
SRaised by the operations supervisor

Plant view · biological treatment

Aeration basin 1
Aeration basin 2Elevated
Secondary clarifier 1
Secondary clarifier 2

01 · Rounds and checklists

Shift rounds from a published routine.

A process routine sets what is read, where, and in what range on each shift. Each round is open, in progress or completed, and overdue is worked out from the time.

Sample
Today’s rounds4 Oct 2026
08:00Morning round · biological lineMr KarimiCompleted
14:00Afternoon round · biological lineMr KarimiIn progress
14:00Pretreatment and screens roundShift teamOpen
20:00Night round · biological lineShift teamOpen
Routine Biological line round · published revision 5 · 3 times a day

02 · Readings and trends

Every reading with its time, source and expected range.

Readings, manual or from a data source, belong to a measurement point. A recorded reading is never deleted; a correction is a new record next to the old one.

Dissolved oxygen, aeration basin 2
WW-MP-DO-2 · mg/L
Expected range 1.5–2.5 mg/L

03 · Process conditions

An attention level, and a path to resolution.

A process condition is raised on a unit or stream with routine, elevated, heightened or critical attention. It is active, being monitored, or resolved, and every change keeps its name and time.

RoutineElevatedHeightenedCritical
Low dissolved oxygen in aeration basin 2PC-0118
  1. 4 Oct · 08:50
    Active Attention: elevated · Eng. Sadeghi
  2. 4 Oct · 09:40
    Monitoring Monitor until the afternoon round
  3. 4 Oct · 14:20
    Resolved DO in range; blower 2 to be inspected

04 · Actions and outcomes

What was done, and what it changed.

Operational actions and outcome assessments are separate, lasting records. Six months later you can still see what you did about the oxygen drop, and whether it worked.

Sample
Operational actionBlower 3 (standby) put into serviceWW-BL-03 · Mr Karimi · 09:05
Outcome assessmentBasin 2 dissolved oxygen reached 1.8 mg/L after 40 minutesEffective · Eng. Sadeghi · 09:45

05 · From observation to repair

An observation that becomes a repair request keeps its context.

When the operator sees the problem is in the equipment, the observation becomes a work request. The unit, the reading and the photo stay attached, so the maintenance supervisor doesn’t have to ask again.

Sample
Observation · OB-0451
Unusual noise and vibration, aeration blower 2
Work request · WR-2324Submitted
Inspect aeration blower 2
Equipment
WW-BL-02
Unit
Aeration basin 2
Related reading
WW-MP-DO-2 · 0.9 mg/L
Process condition
PC-0118

Connections

Where this connects

Operations works on the same plant model: readings on measurement points, conditions on units and streams, and requests flowing to maintenance.

  1. Round and readingsWW-MP-DO-2 · 0.9 mg/L
  2. Process conditionAeration basin 2 · elevated
  3. Work requestFrom an observation, with context
  4. Chemical usageHypochlorite · litres per day

If someone recommended Waiotech to you, the next step is a short conversation.

Tell us about your plant and how you work today, and we’ll show you Waiotech on work like yours.